✨ New Arrivals Just Dropped!Explore
AmScope IN480 Series Inverted Infinity-Corrected Fluorescence Trinocular Compound Microscope with Global Shutter Digital Camera
HomeStore

AmScope IN480 Series Inverted Infinity-Corrected Fluorescence Trinocular Compound Microscope with Global Shutter Digital Camera

AmScope IN480 Series Inverted Infinity-Corrected Fluorescence Trinocular Compound Microscope with Global Shutter Digital Camera

Select Magnification Power
Select Camera Type
Select Camera Pixel
From $3,693.90

Original: $10,553.99

-65%
AmScope IN480 Series Inverted Infinity-Corrected Fluorescence Trinocular Compound Microscope with Global Shutter Digital Camera

$10,553.99

$3,693.90

The Story

The IN480T-FL is our top-of-the-line inverted epi-fluorescence microscope, accommodating diverse observation methods including brightfield, phase-contrast, and epi-fluorescence. The inverted form and modular stage design allow for a wide range of specimen mounts and containers. A wide range of customizations in the Koehler transmitted illumination system provide flexibility and precise control to allow you to achieve optimal results. The reliable and intuitive design ensure you will spend more time focused on your research.

Optics

The infinity-corrected optical system eliminates optical errors when using filters and other in-line components, ensuring highly precise images. Five brightfield objective lenses provide a wide magnification range from 40X to 600X, with plan-achromatic corrections for high resolution, accurate colors, and edge-to-edge sharpness. Additionally, three phase-ring equipped objective lenses can be used for phase-contrast observation.

Viewing Head

The viewing head has a 45&deg incline and Siedentopf interpupillary adjustment for flexibility and comfort. The CX series photo-port uses interchangeable camera mounts to support a variety of imaging solutions. The included 23mm tube mount accommodates our huge selection of microscopy cameras with 23mm reduction lenses. Several optional mounting adapters are available for C-mount cameras, including mounts with integrated reduction to optimize field-of-view based on sensor formats. The viewing platform is equipped with a sliding shutter to isolate the light path when using a camera, avoiding stray light from the oculars.

Koehler Transmitted Illumination

The Koehler transmitted illumination system consists of a centerable 30W halogen lamp, a field lens with iris, and a centerable, height-adjustable condenser with iris. This allows for highly-efficient, optimized illumination for maximum resolution and contrast. The swing-out condenser mount allows the entire condenser assembly to be laterally rotated out of the way for easier specimen placement, and for larger containers. A slide-in annulus board provides two centerable phase-contrast annuli, as well as an open setting for brightfield or for use with colored filters for band-isolation or color-correction.

Epi-fluorescence Illumination

A 100W mercury-vapor episcopic illuminator provides wide-spectrum lighting for fluorescence excitation. Two filter blocks can be mounted and alternated during observation. Blue and green excitation blocks are included to cover a wide range of common fluorophores.

Filters
Filter Set Excitation Center Wavelength / Bandwidth Dichromatic Mirror Cut-on Wavelength Emission Center Wavelength / Bandwidth
B1 480nm/30nm 505nm 535nm/40nm
Common Stains: Alexa Fluor 488, Cy2, FITC
G1 560nm/40nm 600nm 635nm/60nm
Common Stains: Texas Red, Cy3.5, Mito Tracker Red
Mercury HBO Excitation

Mercury HBO lamps produce a wide spectrum of wavelengths, including ultraviolet. While this fluorescent light-source can excite fluorophores throughout its entire spectrum, there are peak wavelengths with optimal output. The included filter blocks will accommodate a wide range of fluorophores, although the nature of mercury arc lamps limits effectiveness outside of the peak wavelengths.

Band Peak Wavelength
UV 334nm, 365nm
V 405nm
B 436nm
G 546nm
Y 578nm

Specifications

Technical drawings with measurements (in mm)


Optical System Infinity-corrected
Head Trinocular, 45° incline
Interpupillary Adjustment Siedentopf compensation-free gemel, 50mm-76mm
Ocular Diameter 30mm
Eyepieces 10X FN22mm plan wide-field
Photo-port CX-type height-adjustable, 23mm tube
Objective Turret quintuple
Focusing System
Focus Adjustment Coaxial Coarse/Fine, adjustable tension
Fine Division 0.002mm
Coarse Stroke 38mm
Fine Stroke 0.2mm
Stage fixed-height, mechanical X-Y translation
Stage Dimensions 160mm x 250mm
stage extension: 70mm x 180mm
Stage X-Y Travel Range 120mm x 80mm
Specimen Holders Terasaki plate, Petri dish
Transmitted Illumination 6V 30W halogen
variable intensity
centerable lamp
Condenser NA 0.3, centerable
Condenser Working Distance 72mm maximum
Phase Contrast Annuli 4X/10X and 20X/40X
Power 90-240VAC 50/60Hz wide-band for international use

Objective Lenses

Magnification Corrections NA Working Distance Cover-glass Thickness
4X plan achromatic 0.13 10.4mm 1.5mm
10X plan achromatic 0.25 7.30mm 1.5mm
20X plan achromatic 0.40 6.79mm 1.5mm
40X plan achromatic 0.60 3.08mm 1.5mm
60X plan achromatic 0.70 1.71mm 1.5mm
10X phase-ring 0.25 7.30mm 1.5mm
20X phase-ring 0.40 6.80mm 1.5mm
40X phase-ring 0.60 3.08mm 1.5mm

Magnification Chart

Eyepiece Objective
4X 10X 20X 40X 60X
10X 40X 100X 200X 400X 600X

Contents

  • One microscope
  • One photo port
  • One mechanical stage attachment
  • One condenser
  • Five brightfield objective lenses
  • Three phase-contrast objective lenses
  • One pair of 10X eyepieces
  • One glass stage insert
  • One metal stage insert
  • Three specimen holders
  • One phase-contrast annulus board
  • One centering telescope
  • Two bulbs
  • Two power cables
  • One dust cover
  • One fluorescence lamp housing
  • One power supply for fluorescence lamp
  • One mercury HBO bulb
  • One B1 filter block
  • One G1 filter block
  • One UV-blocking light shild
  • AmScope IN480 Series Inverted Infinity-Corrected Fluorescence Trinocular Compound Microscope with Global Shutter Digital Camera - Image 2

    Details & Craftsmanship

    Every detail has been carefully considered to bring you the perfect product.

    AmScope IN480 Series Inverted Infinity-Corrected Fluorescence Trinocular Compound Microscope with Global Shutter Digital Camera - Image 3

    Details & Craftsmanship

    Every detail has been carefully considered to bring you the perfect product.

    AmScope IN480 Series Inverted Infinity-Corrected Fluorescence Trinocular Compound Microscope with Global Shutter Digital Camera - Image 4

    Details & Craftsmanship

    Every detail has been carefully considered to bring you the perfect product.

    AmScope IN480 Series Inverted Infinity-Corrected Fluorescence Trinocular Compound Microscope with Global Shutter Digital Camera - Image 5

    Details & Craftsmanship

    Every detail has been carefully considered to bring you the perfect product.

    AmScope IN480 Series Inverted Infinity-Corrected Fluorescence Trinocular Compound Microscope with Global Shutter Digital Camera - Image 6

    Details & Craftsmanship

    Every detail has been carefully considered to bring you the perfect product.

    AmScope IN480 Series Inverted Infinity-Corrected Fluorescence Trinocular Compound Microscope with Global Shutter Digital Camera - Image 7

    Details & Craftsmanship

    Every detail has been carefully considered to bring you the perfect product.

    AmScope IN480 Series Inverted Infinity-Corrected Fluorescence Trinocular Compound Microscope with Global Shutter Digital Camera - Image 8

    Details & Craftsmanship

    Every detail has been carefully considered to bring you the perfect product.

    AmScope IN480 Series Inverted Infinity-Corrected Fluorescence Trinocular Compound Microscope with Global Shutter Digital Camera - Image 9

    Details & Craftsmanship

    Every detail has been carefully considered to bring you the perfect product.

    AmScope IN480 Series Inverted Infinity-Corrected Fluorescence Trinocular Compound Microscope with Global Shutter Digital Camera - Image 10

    Details & Craftsmanship

    Every detail has been carefully considered to bring you the perfect product.

    Description

    The IN480T-FL is our top-of-the-line inverted epi-fluorescence microscope, accommodating diverse observation methods including brightfield, phase-contrast, and epi-fluorescence. The inverted form and modular stage design allow for a wide range of specimen mounts and containers. A wide range of customizations in the Koehler transmitted illumination system provide flexibility and precise control to allow you to achieve optimal results. The reliable and intuitive design ensure you will spend more time focused on your research.

    Optics

    The infinity-corrected optical system eliminates optical errors when using filters and other in-line components, ensuring highly precise images. Five brightfield objective lenses provide a wide magnification range from 40X to 600X, with plan-achromatic corrections for high resolution, accurate colors, and edge-to-edge sharpness. Additionally, three phase-ring equipped objective lenses can be used for phase-contrast observation.

    Viewing Head

    The viewing head has a 45&deg incline and Siedentopf interpupillary adjustment for flexibility and comfort. The CX series photo-port uses interchangeable camera mounts to support a variety of imaging solutions. The included 23mm tube mount accommodates our huge selection of microscopy cameras with 23mm reduction lenses. Several optional mounting adapters are available for C-mount cameras, including mounts with integrated reduction to optimize field-of-view based on sensor formats. The viewing platform is equipped with a sliding shutter to isolate the light path when using a camera, avoiding stray light from the oculars.

    Koehler Transmitted Illumination

    The Koehler transmitted illumination system consists of a centerable 30W halogen lamp, a field lens with iris, and a centerable, height-adjustable condenser with iris. This allows for highly-efficient, optimized illumination for maximum resolution and contrast. The swing-out condenser mount allows the entire condenser assembly to be laterally rotated out of the way for easier specimen placement, and for larger containers. A slide-in annulus board provides two centerable phase-contrast annuli, as well as an open setting for brightfield or for use with colored filters for band-isolation or color-correction.

    Epi-fluorescence Illumination

    A 100W mercury-vapor episcopic illuminator provides wide-spectrum lighting for fluorescence excitation. Two filter blocks can be mounted and alternated during observation. Blue and green excitation blocks are included to cover a wide range of common fluorophores.

    Filters
    Filter Set Excitation Center Wavelength / Bandwidth Dichromatic Mirror Cut-on Wavelength Emission Center Wavelength / Bandwidth
    B1 480nm/30nm 505nm 535nm/40nm
    Common Stains: Alexa Fluor 488, Cy2, FITC
    G1 560nm/40nm 600nm 635nm/60nm
    Common Stains: Texas Red, Cy3.5, Mito Tracker Red
    Mercury HBO Excitation

    Mercury HBO lamps produce a wide spectrum of wavelengths, including ultraviolet. While this fluorescent light-source can excite fluorophores throughout its entire spectrum, there are peak wavelengths with optimal output. The included filter blocks will accommodate a wide range of fluorophores, although the nature of mercury arc lamps limits effectiveness outside of the peak wavelengths.

    Band Peak Wavelength
    UV 334nm, 365nm
    V 405nm
    B 436nm
    G 546nm
    Y 578nm

    Specifications

    Technical drawings with measurements (in mm)


    Optical System Infinity-corrected
    Head Trinocular, 45° incline
    Interpupillary Adjustment Siedentopf compensation-free gemel, 50mm-76mm
    Ocular Diameter 30mm
    Eyepieces 10X FN22mm plan wide-field
    Photo-port CX-type height-adjustable, 23mm tube
    Objective Turret quintuple
    Focusing System
    Focus Adjustment Coaxial Coarse/Fine, adjustable tension
    Fine Division 0.002mm
    Coarse Stroke 38mm
    Fine Stroke 0.2mm
    Stage fixed-height, mechanical X-Y translation
    Stage Dimensions 160mm x 250mm
    stage extension: 70mm x 180mm
    Stage X-Y Travel Range 120mm x 80mm
    Specimen Holders Terasaki plate, Petri dish
    Transmitted Illumination 6V 30W halogen
    variable intensity
    centerable lamp
    Condenser NA 0.3, centerable
    Condenser Working Distance 72mm maximum
    Phase Contrast Annuli 4X/10X and 20X/40X
    Power 90-240VAC 50/60Hz wide-band for international use

    Objective Lenses

    Magnification Corrections NA Working Distance Cover-glass Thickness
    4X plan achromatic 0.13 10.4mm 1.5mm
    10X plan achromatic 0.25 7.30mm 1.5mm
    20X plan achromatic 0.40 6.79mm 1.5mm
    40X plan achromatic 0.60 3.08mm 1.5mm
    60X plan achromatic 0.70 1.71mm 1.5mm
    10X phase-ring 0.25 7.30mm 1.5mm
    20X phase-ring 0.40 6.80mm 1.5mm
    40X phase-ring 0.60 3.08mm 1.5mm

    Magnification Chart

    Eyepiece Objective
    4X 10X 20X 40X 60X
    10X 40X 100X 200X 400X 600X

    Contents

  • One microscope
  • One photo port
  • One mechanical stage attachment
  • One condenser
  • Five brightfield objective lenses
  • Three phase-contrast objective lenses
  • One pair of 10X eyepieces
  • One glass stage insert
  • One metal stage insert
  • Three specimen holders
  • One phase-contrast annulus board
  • One centering telescope
  • Two bulbs
  • Two power cables
  • One dust cover
  • One fluorescence lamp housing
  • One power supply for fluorescence lamp
  • One mercury HBO bulb
  • One B1 filter block
  • One G1 filter block
  • One UV-blocking light shild
    AmScope IN480 Series Inverted Infinity-Corrected Fluorescence Trinocular Compound Microscope with Global Shutter Digital Camera | AmScope